ARBORINNOVATIONS

Cubee sensors at the National Museum of Modern Art, Zagreb

From sensor to decision.

We build IoT sensors, software and AI for museums, hospitals and agriculture, plus 3D games for children. All in our own workshop, from the enclosure to the screen.

Cubee microclimate sensor, hexagonal enclosure with a screen and air vents
Screen with live readings
Sensors: T, RH, CO₂, TVOC, IAQ
Biodegradable plastic enclosure
Drag the model to rotate it

Room 14, temperature

22.6°C

Room 14, humidity

49.6% RH

Room 14, CO₂ (above 1,000)

1,934ppm

Readings since January 2024

2,346,338

Four fields, one workshop

The same team designs the enclosure, writes the firmware, builds the app and models the 3D world for the game.

Beehive on an IoT scale with a solar panel (3D render)

Agriculture

Apiaries and fields

Solar-powered hive scales and weather stations.

HealthSec platform home page

Healthcare

Hospitals

Room microclimate, NIS2 and GDPR compliance with the HealthSec platform, and video consultations in Video Clinic.

Roman statues at the Narona Archaeological Museum

Museums

Museums and heritage

Protecting exhibits, the Titus AI historian and documentation in Sonda.

Crystal Isle from the GamingArena game

Games

Games for children

Five free 3D browser games, with no ads and no sign-up.

How a reading travels

From the air in a display case to a report on the curator’s desk. We build every step ourselves and know where your data is.

  1. Sensor

    Cubee measures T, RH, CO₂, TVOC and IAQ continuously, not once a day.

  2. Gateway

    Zigbee or LoRa network, no cables and no drilling.

  3. Database

    Readings are stored on a server, each with its time and place.

  4. App

    Staff are alerted as soon as humidity or CO₂ leave the safe range.

  5. AI report

    The system writes reports per sensor and for the whole institution.

Sensors already at work

Cubee devices at the National Museum of Modern Art in Zagreb report temperature, humidity and CO₂ every few minutes. The chart shows their real readings from 2 and 3 June 2025.

2,346,338

readings in one museum since January 2024

Relative humidity per hour, 2 Jun 2025, 09:00

40 % 45 % 50 % 55 % 08:0014:0020:0002:0007:00
Real Cubee sensor readings, hourly average. CO₂ above 1,000 ppm is marked in words and colour.
RoomHumidityTemp.CO₂
Room 1451,7 %22.6 °C1,934 ppm high
Room 1143,2 %29.3 °C1,599 ppm high
Room 1245,6 %26.4 °C584 ppm

Products in use

Each was built for a real place and a real problem, and each is publicly available.

Cubee taken apart: lid with screen, circuit board and base

How we work

We don’t sell a box with a sensor. Every system follows the same path, from floor plan to report.

  1. On site

    We walk the space and mark on the floor plan where to measure: display cases, stores, halls, rooms.

  2. Enclosure and electronics

    We print the enclosures ourselves from biodegradable plastic and choose the sensors for that space.

  3. Installation

    We install the sensors and gateway ourselves, with no cables or drilling where that isn’t allowed.

  4. Data and AI

    Readings arrive in the app, the system reports deviations while they last and writes the reports.

Have a space that needs monitoring?

Describe it in a few sentences. We’ll reply with a proposal for sensors, the app and a rough estimate.

Send an enquiry ai@arborinnovations.hr